To enable easy decoding PIDs should be set as: Video 256, Audio, 257, PMT 32 or 4095, PCR 256 or 258. Service
            Name should be set to CallSign. PMT PIDs 4000 - 4010 should not be used. Users are encouraged to experiment
            with higher-order DVB-S2 modes at lower symbol rates (for example 333 KS 32APSK) to conserve bandwidth for
            other users.

            On Wednesdays (UTC time), experimenters are encouraged to try other modes - perhaps 6 MS using the whole
            transponder for brief (less than 10 minute) periods. It is essential that users to announce their plans on the chat
            room page, and to always monitor it.


            Beacon Settings
            The beacon will run 24/7
            DATV Beacon DVB-S2 parameters:

                   • Center Frequency: 10 4915 MHz
                   • DVB-S2
                   • QPSK 4/5 FEC
                   • 1500 kSymbols
                   • RollOff = 0,25
                   • Pilots = off
                   • min. C/N = 4.6dB
                   • Datarate 2,383 MBit
             Initial bandplan  (will be revised after recent changes)

             1. the maintenance uplink will only be used very occasionally, but users are requested to give it
             absolute priority when notified.
             2. DVB-S2 users are requested to use the steepest roll-off that their equipment is capable of to
             reduce the possibility of adjacent channel interference.

             3. recommended spot frequencies for various usages and symbol rates are listed below
                         Symbol    Uplink   Downlink
            Role                                               Designer notes
                          Rate      freq      freq
            beacon wide 2MS                10492.5   2MS1    Initial Beacon Mode
            Beacon
            Narrow      1.5MS              10491.5   1MS1    DATV DVB-S2 BEACON
            simplex     2MS       2403.0   10492.5   2MS1    Only available outside beacon hours
            simplex     2MS       2406.0   10495.5   2MS2
            simplex     1MS       2402.25  10491.75  1MS1    Only available outside beacon hours
                                                             Only available outside beacon hours or when
            simplex     1MS       2403.75  10493.25  1MS2
                                                             beacon is in narrow mode
            simplex     1MS       2405.25  10494.75  1MS3    Only available if 2MS2 not in use
            simplex     1MS       2406.75  10496.25  1MS4    Only available if 2MS2 not in use
            simplex     333KS     2407.75  10497.25  333KS1
            simplex     333KS     2408.25  10497.75  333KS2
            simplex     333KS     2408.75  10498.25  333KS3
            simplex     333KS     2409.25  10498.75  333KS4
            simplex     125KS     2407.625 10497.125  125KS1 Only available if 333KS1 not in use
            simplex     125KS     2407.875 10497.375  125KS2 Only available if 333KS1 not in use
            simplex     125KS     2408.125 10497.625  125KS3 Only available if 333KS2 not in use
            simplex     125KS     2408.375 10497.875  125KS4 Only available if 333KS2 not in use
            simplex     125KS     2408.625 10498.125  125KS5 Only available if 333KS3 not in use
            simplex     125KS     2408.875 10498.375  125KS6 Only available if 333KS3 not in use
            simplex     125KS     2409.125 10498.625  125KS7 Only available if 333KS4 not in use
            simplex     125KS     2409.375 10498.875  125KS8 Only available if 333KS4 not in use